Certifications

Isopan: quality assurance. Certified.

Isopan companies are ISO 9001 certified and technical compliance of products is guaranteed according to the standards requested by the markets of reference. 

As a result of their technical features, Ispoan panels protect buildings against fires, thus preventing the fire from spreading and resulting damage to the structures. The rock wool and polyurethane foam panels by Isopan offer the best fire reaction performance available on the market (tested in accordance with EN 14509 and EN 13501).

Besides the certified fire panels, you will also find products with outstanding soundproofing performance amongst the range of products by Isopan: sound attenuation and insulation from one room to the other.

Isopan fears neither water nor air: the panels are also certified to guarantee the best resistance against wind and pouring rain.

 

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

Fire Reaction Classification

FIRE REACTION CERTIFICATION: refers to the reaction of materials to the fire in the actual conditions of final application, with special focus on the degree of participation in the fire. Reaction to fire is a passive fire protection measure that carries out its main effects during the first propagation of the fire with the aim of limiting ignition of materials and propagation of the said fire (standard EN 13501-1)

Isopan panels limit ignition and propagation of flames in the event of a fire.

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

LEGEND
  • Not producible
  • No certificate
  • Certified producible
  • Certified by extension
  • Performance granted with technical note
Fire Reaction Classification Insulation Category Products Thickness (mm)
303540506070728092100102120150170180200
A2s1d0 Mineral Wool
wall
Isofire Wall
A2s1d0 Mineral Wool
wall
Isofire Wall Plissé
A2s1d0 Mineral Wool
roof
Isofire Roof
Bs1d0 (1) PIR
wall
Isoclass
Bs1d0 (1) PIR
roof
Isotego
Bs1d0 (1) PIR
roof
Isotap
Bs1d0 (1) PIR
wall
Isofrigo, Isofrozen, Isofrozen HT
Bs1d0 (1) PIR
roof
Isocop
Bs1d0 (1) PIR
wall
Isoparete Box, Isoparete Plissé
Bs1d0 (1) PIR
wall
Isobox
Bs1d0 (1) PIR
wall
Isoparete Plus (Pe - Ro - Pg)
Bs1d0 (1) PIR
wall
Isoparete Evo (Box - Plissé - Double)
Bs2d0 PU
wall
Isoparete Box, Isoparete Piano, Isoparete Plissé
Bs2d0 PU
wall
Isoclass from 72 mm to 102 mm
Bs2d0 PU
roof
Isotego
Bs2d0 PU
roof
Isotap
Bs2d0 PIR
roof
Isocop
Bs2d0 PIR
wall
Isoparete Evo (Box - Plissé - Double)
Bs2d0 PIR
roof
Isovela & Isovela Classic
Bs2d0 PIR
wall
Isobox, Isopiano, Isorighe
Bs2d0 PIR
wall
Isoparete Box, Isoparete Piano, Isoparete Plissé
Bs2d0 PIR
wall
Isoparete Plus (Pe - Ro - Pg)
Bs2d0 PIR
wall
Isoclass from 72 mm to 102 mm
Bs2d0 PIR
wall
Isofrigo, Isofrozen, Isofrozen HT
Bs3d0 PU
wall
Isobox, Isopiano, Isorighe
Bs3d0 PU
wall
Isofrigo
Bs3d0 PU
roof
Isocop
Cs3d0 PU
roof
Isotego
Cs3d0 PU
roof
Isotap
Cs3d0 PU
roof
Isodomus & Isodomus Classic
Cs3d0 PU
roof
Isocop
The Fire Reaction Classes are obtained according to EN 13501-1 and EN 14509/2013
(1) Special formula - For further information, please contact Isopan.

Fire Resistance Classification

FIRE RESISTANCE CERTIFICATION: refers to the load-bearing capacity and separating ability in case of fire for structural (e.g. walls, floors) and non-structural (e.g. doors, partitions) separation elements. Fire resistance is a fire protection measure to pursue in order to ensure an adequate level of safety of a building in case of fire (reference standard EN 13501-2.)

Isopan panels assure adequate fire resistance in case of fire.

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

LEGEND
  • Not producible
  • No certificate
  • Certified producible
  • Certified by extension
  • Performance granted with technical note
Fire Resistance Classification Insulation Category Products Thickness (mm)
303540506070728092100102120150170180200
REI120 Mineral Wool
roof
Isodeck PVSteel
REI120 Mineral Wool
roof
Isofire Roof
REI60 Mineral Wool
roof
Isofire Roof
REI60 Mineral Wool
roof
Isofire Roof Fono
REI30 Mineral Wool
roof
Isofire Roof
REI30 PIR
roof
Isocop
REI15 PU
roof
Isocop
REI15 PIR
roof
Isocop
EI180 Mineral Wool
wall
Isofire Wall
EI120 Mineral Wool
wall
Isofire Wall
EI90 Mineral Wool
wall
Isofire Wall
EI60 Mineral Wool
wall
Isofire Wall
EI60 PIR
wall
Isofrigo, Isofrozen, Isofrozen HT
EI30 Mineral Wool
wall
Isofire Wall
EI30 PIR
wall
Isoparete Box, Isoparete Piano, Isoparete Plissé
EI30 PIR
wall
Isofrigo, Isofrozen, Isofrozen HT
EI30 PIR
wall
Isoparete Evo (Box - Plissé - Double)
EI20 PIR
wall
Isobox, Isopiano, Isorighe
EI20 PIR
wall
Isoparete Box, Isoparete Piano, Isoparete Plissé
EI20 PIR
wall
Isofrigo, Isofrozen, Isofrozen HT
EI20 PIR
wall
Isoparete Evo (Box - Plissé - Double)
EI15 Mineral Wool
wall
Isofire Wall
EI15 PIR
wall
Isobox, Isopiano, Isorighe
EW60 PU
wall
Isobox, Isopiano, Isorighe
The Fire Reaction Classes are obtained according to EN 13501-2 and EN 14509/2013
 

Sound-insulation performance

SOUND INSULATION CERTIFICATION: represents the ability to isolate sound from one room to another. Laboratory measurements of airborne sound insulation is carried out according to EN ISO 140-3, UNI EN ISO 14140-2, UNI EN ISO 1793 Part 2 and 3 and UNI EN ISO 717-1

Isopan panels limit sound from one room to another.

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

LEGEND
  • Not producible
  • No certificate
  • Certified producible
  • Certified by extension
  • Performance granted with technical note
Sound-insulation performance Insulation Category Products Thickness (mm)
303540506070728092100102120150170180200
Rw=35dB Mineral Wool
roof
Isofire Roof Fono
Rw=35dB Mineral Wool
wall
Isofire Wall Fono
Rw=34dB Mineral Wool
wall
Isofire Wall Fono
Rw=34dB Mineral Wool
roof
Isofire Roof Fono
Rw=30dB Mineral Wool
wall
Isofire Wall
Rw=30dB Mineral Wool
roof
Isofire Roof
Rw=31dB Mineral Wool
roof
Isofire Roof Fono
Rw=29dB PIR
wall
Isoparete Plissé
Rw=29dB PIR
roof
Isocop
Rw=24dB Polyurethane foam
roof
Isodomus & Isodomus Classic

The sound insulation and sound absorbing values are obtained according to EN ISO 354, EN ISO 717-1 and EN 1793.

Sound-absorption performance

SOUND ABSORPTION CERTIFICATION: represents the sound power portion, which, once it passes through the wall, it will no longer go back to the emitter environment and can take on a unit value as a maximum value. Measurement in a reverberation room of the sound absorption coefficient is carried out according to UNI EN ISO 354, UNI EN 1793-1 and UNI EN 1793-3.

Isopan panels are able to dampen sound reverberation, thus improving comfort in the area.

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

LEGEND
  • Not producible
  • No certificate
  • Certified producible
  • Certified by extension
  • Performance granted with technical note
Sound-absorption performance Insulation Category Products Thickness (mm)
303540506070728092100102120150170180200
αw=1 Mineral Wool
wall
Isofire Wall Fono
αw=1 Mineral Wool
roof
Isofire Roof Fono

The sound insulation and sound absorbing values are obtained according to EN ISO 354, EN ISO 717-1 and EN 1793.

B-roof | Reaction to fire

B-ROOF CERTIFICATION: represents the specific assessment of external fire exposure to roofs and the fire reaction class of the installed photovoltaic module. The test methods and performance against fire are detailed in UNI CEN/TS 1187. The circular of the Fire Department accepts use of cover packages classified according to regulations such as B-roof (t2), B-roof (t3) and B-roof (t4). Identification of the test method used is indicated by (t1), (t2), (t3), and (t4), where the progressive number does not indicate more or less resistance to fire, but refers to the different test method. Performance is indicated by the letters: B-roof indicates maximum possible classification, whereas F-roof indicates no performance.

Isopan panels reduce the risk of fire spreading on roof coverings, thus making them suitable for installation of photovoltaic panels.

ATTENTION: The performances declared in the tables below, which are associated with different types of insulation, can vary based on the production of the building, in accordance with local and national regulations in force. Kindly check with Isopan. If not specifically requested, no performance will be provided.

 

LEGEND
  • Not producible
  • No certificate
  • Certified producible
  • Certified by extension
  • Performance granted with technical note
B-roof | Reaction to fire Insulation Category Products Thickness (mm)
303540506070728092100102120150170180200
Broof (t1) PU
roof
Isodeck PVSteel
Broof (t3) PU
roof
Isoray
Broof (t3) PU
roof
Isocop
Broof (t3) PU
roof
Isodomus & Isodomus Classic
Broof (t3) PU
roof
Isogrecata
Broof (t4) PU
roof
Isocop

EN © 2016 Manni Group S.p.A | VAT number 00286420609

Privacy Policy